Installing Flatty
To install the sensor, follow the steps below:
- Sensors are turned on by default unless otherwise agreed. If off, follow this guide to switch them on.
- Identify the desired installation area on the flat roof.
- The sensor should be under the insulation, but above the bottom membrane.
- There should be no drainage, pipes or similar in the insulation directly above the sensor.
- Cut a round hole in the insulation with a diameter of 12 cm, which is slightly larger than the sensor. This allows you to easily place the sensor.
- Register the sensor. Remember to use the number from the blueprint for location description, or any other appropriate marking.
- Put insulation above the sensor.

Please note:
- The sensor should never be exposed directly to rain and shall be covered immediately upon installation